{"id":249,"date":"2020-09-01T22:44:50","date_gmt":"2020-09-01T22:44:50","guid":{"rendered":"https:\/\/equitest.co\/testing\/?p=249"},"modified":"2025-12-12T21:57:51","modified_gmt":"2025-12-12T21:57:51","slug":"tecnicas-y-metodologias-para-la-evaluacion-de-pararrayos-sa-30i","status":"publish","type":"post","link":"https:\/\/equitest.co\/testing\/2020\/09\/01\/tecnicas-y-metodologias-para-la-evaluacion-de-pararrayos-sa-30i\/","title":{"rendered":"T\u00e9cnicas y Metodolog\u00edas en la Evaluaci\u00f3n de Pararrayos"},"content":{"rendered":"<div id=\"pl-249\" class=\"panel-layout\">\n<div id=\"pg-249-0\" class=\"panel-grid panel-no-style\" data-style=\"{&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;,&quot;cell_alignment&quot;:&quot;flex-start&quot;}\">\n<div id=\"pgc-249-0-0\" class=\"panel-grid-cell\" data-weight=\"1\">\n<div id=\"panel-249-0-0-1\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-last-child\" data-index=\"1\" data-style=\"{&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;}\">\n<div class=\"textwidget\">\n<p style=\"text-align: center;\"><strong><span style=\"color: #008000;\">EQUITEST COLOMBIA SAS Representante de la marca SCOPE, se complace en ofrecer el equipo de prueba para <\/span><\/strong><\/p>\n<p style=\"text-align: center;\"><strong><span style=\"color: #008000;\">pararrayos de nueva generaci\u00f3n SA 30i+, Premio al mejor producto en la categor\u00eda general ELECRAMA 2016<\/span><\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-278 alignleft\" src=\"https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/foto-blog.jpg\" alt=\"\" width=\"471\" height=\"353\" srcset=\"https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/foto-blog.jpg 975w, https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/foto-blog-300x225.jpg 300w, https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/foto-blog-768x576.jpg 768w, https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/foto-blog-150x112.jpg 150w\" sizes=\"(max-width: 471px) 100vw, 471px\" \/><\/p>\n<p><strong>T\u00c9CNICAS Y METODOLOG\u00cdAS PARA LA EVALUACI\u00d3N DE\u00a0PARARRAYOS<\/strong><\/p>\n<p>El pararrayos se coloca como un guardi\u00e1n, en la entrada de las l\u00edneas de transmisi\u00f3n de una subestaci\u00f3n. El pararrayos protege equipos costosos como transformadores y reactores brindando protecci\u00f3n, y garantizando la seguridad, en condiciones adversas a sobre tensiones, impulsos de tensi\u00f3n a alta frecuencia (Tipo rayo), etc.<\/p>\n<p>En las \u00faltimas d\u00e9cadas, los pararrayos han evolucionado del uso de carburo de silicio al \u00f3xido de zinc (ZnO). Si bien ZnO ofrece una protecci\u00f3n superior, sin embargo, con bloques ZnO tienden a fallar cr\u00edticamente una vez que comienza su degradaci\u00f3n.<\/p>\n<p>Algunos de los factores comunes que conducen a la degradaci\u00f3n de los bloques de ZnO son los impulsos tipo rayos, sobretensiones, acumulaci\u00f3n de humedad, contaminaci\u00f3n ambiental y el envejecimiento gradual de los pararrayos.<\/p>\n<p>Como consecuencia de los factores antes mencionados, la resistencia efectiva de los pararrayos reduce significativamente lo que lleva a un aumento en la corriente de fuga (I<sub>t<\/sub>) y, por lo tanto, tambi\u00e9n\u00a0las p\u00e9rdidas\u00a0I<sup>2<\/sup>R.<\/p>\n<p>Las p\u00e9rdidas\u00a0 de I<sup>2<\/sup>R generan m\u00e1s calor y aceleran el envejecimiento, lo que a su vez disminuye la resistencia efectiva de los pararrayos, lo que finalmente conduce a su falla completa.<\/p>\n<p><strong>Circuito El\u00e9ctrico Equivalente del Pararrayos\u00a0<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-259 aligncenter\" src=\"https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/Captura-272x300-1.jpg\" alt=\"\" width=\"272\" height=\"300\" srcset=\"https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/Captura-272x300-1.jpg 272w, https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/Captura-272x300-1-136x150.jpg 136w\" sizes=\"(max-width: 272px) 100vw, 272px\" \/><\/p>\n<div>\n<div style=\"text-align: justify;\">Comprender el circuito el\u00e9ctrico equivalente de los pararrayos es fundamental para controlar su salud y obtener un rendimiento \u00f3ptimo.<\/div>\n<\/div>\n<div style=\"text-align: left;\">\n<ul>\n<li>En condici\u00f3n normal se comporta como un aislador.<\/li>\n<li>En condici\u00f3n de alto voltaje se comporta como un conductor.<\/li>\n<li>R: Valor de componente resistiva.<\/li>\n<li>C: Valor de componente capacitiva.<\/li>\n<li>Ir: Corriente Resistiva.<\/li>\n<li>Ic: Corriente Capacitiva.<\/li>\n<li>1 y 2: Puntos de Medida de Corriente.<\/li>\n<li>1. Punto de Alto Voltaje.<\/li>\n<li>2. Punto de Referencia Tierra, as\u00ed como la ubicaci\u00f3n de la medici\u00f3n actual.<\/li>\n<\/ul>\n<p style=\"text-align: justify;\">La componente capacitiva de la corriente de fuga permanece casi constante, es la corriente de fuga resistiva la principal responsable del calentamiento de los bloques ZnO de los pararrayos.<\/p>\n<p style=\"text-align: justify;\"><span style=\"text-align: justify; font-family: inherit; font-size: inherit;\">Con una mayor disipaci\u00f3n de calor, los Bloques de los pararrayos pueden volverse t\u00e9rmicamente inestables y provocar fugas t\u00e9rmicas y tal vez explosiones. Por lo tanto, el monitoreo regular de la corriente de fuga que fluye en los bloques de ZnO es primordial.<\/span><\/p>\n<p><strong style=\"text-align: center; font-family: inherit; font-size: inherit;\"><span class=\"has-inline-color has-luminous-vivid-orange-color\">T\u00e9cnicas Utilizadas<\/span><\/strong><\/p>\n<\/div>\n<div style=\"text-align: left;\"><strong>1. Medici\u00f3n de<\/strong>\u00a0<strong>Tan Delta.<\/strong><\/div>\n<div style=\"text-align: justify;\">Con una degradaci\u00f3n del pararrayos, el\u00a0valor de\u00a0I<sub>r<\/sub> aumenta, lo que resulta en un aumento del \u00e1ngulo Delta que finalmente resulta en un mayor valor del Tan Delta. Monitorear la tendencia del valor Tan Delta forma la base de la t\u00e9cnica de medici\u00f3n Tan Delta.<\/div>\n<div style=\"text-align: left;\">\u00a0<\/div>\n<div style=\"text-align: left;\"><strong>2. Prueba de Resistencia de Aislamiento\/Prueba de Corriente de Fuga CC.<\/strong><\/div>\n<div style=\"text-align: justify;\">En esta t\u00e9cnica, se realiza una prueba de resistencia de aislamiento o prueba de corriente de fuga en la CC que elimina el\u00a0valor\u00a0I<sub>c<\/sub>\u00a0y solo el\u00a0valor\u00a0I<sub>r<\/sub>\u00a0se refleja en los resultados de la medici\u00f3n.\u00a0Esta medici\u00f3n es menos precisa para proporcionar una imagen real de la salud de los pararrayos.<\/div>\n<div style=\"text-align: left;\">\u00a0<\/div>\n<div style=\"text-align: left;\"><strong>3. Medida de Corriente de Fuga Resistiva del Tercer Arm\u00f3nico.<\/strong><\/div>\n<div style=\"text-align: justify;\"><span style=\"text-align: justify; font-family: inherit; font-size: inherit;\">En esta t\u00e9cnica, la corriente de fuga que fluye a trav\u00e9s del cable de tierra se mide con la ayuda de un amper\u00edmetro especializado.\u00a0A partir de la corriente de fuga, se calculan los arm\u00f3nicos de tercer orden a partir de los cuales se deriva el componente resistivo de tercer orden.<\/span><\/div>\n<div>\n<p class=\"has-text-align-justify\" style=\"text-align: justify;\">Esta es la t\u00e9cnica m\u00e1s preferida ya que es una medici\u00f3n On-line, no requiere ning\u00fan retiro del dispositivo a probar.<\/p>\n<p class=\"has-text-align-justify\" style=\"text-align: left;\"><strong><span class=\"has-inline-color has-luminous-vivid-orange-color\">Medici\u00f3n de la Corriente de Fuga Resistiva o P\u00e9rdida de Potencia<\/span><\/strong><\/p>\n<p class=\"has-text-align-justify\" style=\"text-align: justify;\">Seg\u00fan la norma est\u00e1ndar IEC 60099-5 , existen 8 m\u00e9todos diferentes para medir la corriente de fuga resistiva o la p\u00e9rdida de potencia en la t\u00e9cnica de medici\u00f3n de corriente de fuga de AC. Estos 8 m\u00e9todos se clasifican en A1, A2, A3, A4, B1, B2, B3 y C.<\/p>\n<p class=\"has-text-align-justify\" style=\"text-align: justify;\">Mientras que los m\u00e9todos A1 a A4 describen la medici\u00f3n directa de la corriente de fuga resistiva, los m\u00e9todos B1 a B3 describen la determinaci\u00f3n indirecta del componente resistivo mediante un an\u00e1lisis arm\u00f3nico de la corriente de fuga y el m\u00e9todo C explica la determinaci\u00f3n directa de la p\u00e9rdida de potencia.<\/p>\n<p class=\"has-text-align-justify\" style=\"text-align: justify;\">No dude en contactarnos para obtener una explicaci\u00f3n m\u00e1s detallada de cada m\u00e9todo mencionado en IEC 60099-5.\u00a0IEC 60099-5 cl\u00e1usula 6.5 destaca una comparaci\u00f3n detallada de los diversos m\u00e9todos de medici\u00f3n de corriente de fuga.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-260 size-full aligncenter\" src=\"https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/TABLA-3-ARMONICO.png\" alt=\"\" width=\"549\" height=\"299\" srcset=\"https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/TABLA-3-ARMONICO.png 549w, https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/TABLA-3-ARMONICO-300x163.png 300w, https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/TABLA-3-ARMONICO-150x82.png 150w\" sizes=\"(max-width: 549px) 100vw, 549px\" \/><\/p>\n<p style=\"text-align: justify;\">De la tabla anterior se desprende que los m\u00e9todos B1 y B2 ofrecen los mejores resultados en comparaci\u00f3n con otros m\u00e9todos.<\/p>\n<p class=\"has-text-align-justify\" style=\"text-align: justify;\">Sin embargo, el m\u00e9todo B2 proporciona un an\u00e1lisis de salud m\u00e1s preciso del pararrayos en comparaci\u00f3n con el m\u00e9todo B1, ya que el efecto \/ error de los arm\u00f3nicos presentes en el voltaje del sistema se compensa solo en el m\u00e9todo B2.<\/p>\n<p class=\"has-text-align-justify\" style=\"text-align: justify;\">Por lo tanto, podemos concluir que el m\u00e9todo B2 es el mejor m\u00e9todo a seguir al evaluar la salud de los pararrayos.<\/p>\n<p style=\"text-align: left;\"><strong><span class=\"has-inline-color has-luminous-vivid-orange-color\">ALCANCE SA 30i+<\/span><\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-263 aligncenter\" src=\"https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/sa-30i-300x300-1.jpg\" alt=\"\" width=\"300\" height=\"300\" srcset=\"https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/sa-30i-300x300-1.jpg 300w, https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/sa-30i-300x300-1-150x150.jpg 150w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p class=\"has-text-align-justify\" style=\"text-align: justify;\">SCOPE SA 30i+ es un analizador de corriente de fuga inal\u00e1mbrico de \u00faltima generaci\u00f3n dise\u00f1ado para evaluar la vida residual de los pararrayos de \u00f3xido de metal.<\/p>\n<p class=\"has-text-align-justify\" style=\"text-align: justify;\">SA 30i+ mide con precisi\u00f3n y muestra directamente los valores de la corriente de fuga total y la corriente de fuga resistiva del tercer arm\u00f3nico junto con la compensaci\u00f3n arm\u00f3nica seg\u00fan IEC 60099-5-B2.<\/p>\n<p class=\"has-text-align-justify\" style=\"text-align: justify;\">Dise\u00f1ado para trabajar bajo el ruido electrost\u00e1tico hostil que se encuentra en los patios de distribuci\u00f3n de EHV de hasta 765 kV, el SA 30i+ de SCOPE proporciona sin problemas Corriente de fuga resistiva corregida despu\u00e9s de aplicar los factores de correcci\u00f3n necesarios para los cambios en el voltaje y la temperatura del sistema. Para obtener m\u00e1s informaci\u00f3n, visite <a href=\"https:\/\/www.scopetnm.com\/test-and-measurements\/item\/75-sa-30i\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"has-inline-color has-vivid-cyan-blue-color\">https:\/\/www.scopetnm.com\/test-and-measurements\/item\/75-sa-30i<\/span><\/a> o escr\u00edbanos a equitest@equitest.co, Representante de SCOPE en Colombia.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>EQUITEST COLOMBIA SAS Representante de la marca SCOPE, se complace en ofrecer el equipo de prueba para pararrayos de nueva generaci\u00f3n SA 30i+, Premio al mejor producto en la categor\u00eda general ELECRAMA 2016T\u00c9CNICAS Y METODOLOG\u00cdAS PARA LA EVALUACI\u00d3N DE\u00a0PARARRAYOSEl pararrayos se coloca como un guardi\u00e1n, en la entrada de las l\u00edneas de transmisi\u00f3n de una [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":278,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"<div id=\"pl-249\" class=\"panel-layout\"><div id=\"pg-249-0\" class=\"panel-grid panel-no-style\" data-style=\"{&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;,&quot;cell_alignment&quot;:&quot;flex-start&quot;}\"><div id=\"pgc-249-0-0\" class=\"panel-grid-cell\" data-weight=\"1\"><div id=\"panel-249-0-0-1\" class=\"so-panel widget widget_black-studio-tinymce widget_black_studio_tinymce panel-last-child\" data-index=\"1\" data-style=\"{&quot;background_image_attachment&quot;:false,&quot;background_display&quot;:&quot;tile&quot;}\"><div class=\"textwidget\"><p style=\"text-align: center;\"><strong><span style=\"color: #008000;\">EQUITEST COLOMBIA SAS Representante de la marca SCOPE, se complace en ofrecer el equipo de prueba para <\/span><\/strong><\/p><p style=\"text-align: center;\"><strong><span style=\"color: #008000;\">pararrayos de nueva generaci\u00f3n SA 30i+, Premio al mejor producto en la categor\u00eda general ELECRAMA 2016<\/span><\/strong><\/p><p><img class=\" wp-image-278 alignleft\" src=\"https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/foto-blog.jpg\" alt=\"\" width=\"471\" height=\"353\" \/><\/p><p><strong>T\u00c9CNICAS Y METODOLOG\u00cdAS PARA LA EVALUACI\u00d3N DE\u00a0PARARRAYOS<\/strong><\/p><p>El pararrayos se coloca como un guardi\u00e1n, en la entrada de las l\u00edneas de transmisi\u00f3n de una subestaci\u00f3n. El pararrayos protege equipos costosos como transformadores y reactores brindando protecci\u00f3n, y garantizando la seguridad, en condiciones adversas a sobre tensiones, impulsos de tensi\u00f3n a alta frecuencia (Tipo rayo), etc.<\/p><p>En las \u00faltimas d\u00e9cadas, los pararrayos han evolucionado del uso de carburo de silicio al \u00f3xido de zinc (ZnO). Si bien ZnO ofrece una protecci\u00f3n superior, sin embargo, con bloques ZnO tienden a fallar cr\u00edticamente una vez que comienza su degradaci\u00f3n.<\/p><p>Algunos de los factores comunes que conducen a la degradaci\u00f3n de los bloques de ZnO son los impulsos tipo rayos, sobretensiones, acumulaci\u00f3n de humedad, contaminaci\u00f3n ambiental y el envejecimiento gradual de los pararrayos.<\/p><p>Como consecuencia de los factores antes mencionados, la resistencia efectiva de los pararrayos reduce significativamente lo que lleva a un aumento en la corriente de fuga (I<sub>t<\/sub>) y, por lo tanto, tambi\u00e9n\u00a0las p\u00e9rdidas\u00a0I<sup>2<\/sup>R.<\/p><p>Las p\u00e9rdidas\u00a0 de I<sup>2<\/sup>R generan m\u00e1s calor y aceleran el envejecimiento, lo que a su vez disminuye la resistencia efectiva de los pararrayos, lo que finalmente conduce a su falla completa.<\/p><p><strong>Circuito El\u00e9ctrico Equivalente del Pararrayos\u00a0<\/strong><\/p><p><img class=\"size-full wp-image-259 aligncenter\" src=\"https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/Captura-272x300-1.jpg\" alt=\"\" width=\"272\" height=\"300\" \/><\/p><div><div style=\"text-align: justify;\">Comprender el circuito el\u00e9ctrico equivalente de los pararrayos es fundamental para controlar su salud y obtener un rendimiento \u00f3ptimo.<\/div><\/div><div style=\"text-align: left;\"><ul><li>En condici\u00f3n normal se comporta como un aislador.<\/li><li>En condici\u00f3n de alto voltaje se comporta como un conductor.<\/li><li>R: Valor de componente resistiva.<\/li><li>C: Valor de componente capacitiva.<\/li><li>Ir: Corriente Resistiva.<\/li><li>Ic: Corriente Capacitiva.<\/li><li>1 y 2: Puntos de Medida de Corriente.<\/li><li>1. Punto de Alto Voltaje.<\/li><li>2. Punto de Referencia Tierra, as\u00ed como la ubicaci\u00f3n de la medici\u00f3n actual.<\/li><\/ul><p style=\"text-align: justify;\">La componente capacitiva de la corriente de fuga permanece casi constante, es la corriente de fuga resistiva la principal responsable del calentamiento de los bloques ZnO de los pararrayos.<\/p><p style=\"text-align: justify;\"><span style=\"text-align: justify; font-family: inherit; font-size: inherit;\">Con una mayor disipaci\u00f3n de calor, los Bloques de los pararrayos pueden volverse t\u00e9rmicamente inestables y provocar fugas t\u00e9rmicas y tal vez explosiones. Por lo tanto, el monitoreo regular de la corriente de fuga que fluye en los bloques de ZnO es primordial.<\/span><\/p><p><strong style=\"text-align: center; font-family: inherit; font-size: inherit;\"><span class=\"has-inline-color has-luminous-vivid-orange-color\">T\u00e9cnicas Utilizadas<\/span><\/strong><\/p><\/div><div style=\"text-align: left;\"><strong>1. Medici\u00f3n de<\/strong>\u00a0<strong>Tan Delta.<\/strong><\/div><div style=\"text-align: justify;\">Con una degradaci\u00f3n del pararrayos, el\u00a0valor de\u00a0I<sub>r<\/sub> aumenta, lo que resulta en un aumento del \u00e1ngulo Delta que finalmente resulta en un mayor valor del Tan Delta. Monitorear la tendencia del valor Tan Delta forma la base de la t\u00e9cnica de medici\u00f3n Tan Delta.<\/div><div style=\"text-align: left;\">\u00a0<\/div><div style=\"text-align: left;\"><strong>2. Prueba de Resistencia de Aislamiento\/Prueba de Corriente de Fuga CC.<\/strong><\/div><div style=\"text-align: justify;\">En esta t\u00e9cnica, se realiza una prueba de resistencia de aislamiento o prueba de corriente de fuga en la CC que elimina el\u00a0valor\u00a0I<sub>c<\/sub>\u00a0y solo el\u00a0valor\u00a0I<sub>r<\/sub>\u00a0se refleja en los resultados de la medici\u00f3n.\u00a0Esta medici\u00f3n es menos precisa para proporcionar una imagen real de la salud de los pararrayos.<\/div><div style=\"text-align: left;\">\u00a0<\/div><div style=\"text-align: left;\"><strong>3. Medida de Corriente de Fuga Resistiva del Tercer Arm\u00f3nico.<\/strong><\/div><div style=\"text-align: justify;\"><span style=\"text-align: justify; font-family: inherit; font-size: inherit;\">En esta t\u00e9cnica, la corriente de fuga que fluye a trav\u00e9s del cable de tierra se mide con la ayuda de un amper\u00edmetro especializado.\u00a0A partir de la corriente de fuga, se calculan los arm\u00f3nicos de tercer orden a partir de los cuales se deriva el componente resistivo de tercer orden.<\/span><\/div><div><p class=\"has-text-align-justify\" style=\"text-align: justify;\">Esta es la t\u00e9cnica m\u00e1s preferida ya que es una medici\u00f3n On-line, no requiere ning\u00fan retiro del dispositivo a probar.<\/p><p class=\"has-text-align-justify\" style=\"text-align: left;\"><strong><span class=\"has-inline-color has-luminous-vivid-orange-color\">Medici\u00f3n de la Corriente de Fuga Resistiva o P\u00e9rdida de Potencia<\/span><\/strong><\/p><p class=\"has-text-align-justify\" style=\"text-align: justify;\">Seg\u00fan la norma est\u00e1ndar IEC 60099-5 , existen 8 m\u00e9todos diferentes para medir la corriente de fuga resistiva o la p\u00e9rdida de potencia en la t\u00e9cnica de medici\u00f3n de corriente de fuga de AC. Estos 8 m\u00e9todos se clasifican en A1, A2, A3, A4, B1, B2, B3 y C.<\/p><p class=\"has-text-align-justify\" style=\"text-align: justify;\">Mientras que los m\u00e9todos A1 a A4 describen la medici\u00f3n directa de la corriente de fuga resistiva, los m\u00e9todos B1 a B3 describen la determinaci\u00f3n indirecta del componente resistivo mediante un an\u00e1lisis arm\u00f3nico de la corriente de fuga y el m\u00e9todo C explica la determinaci\u00f3n directa de la p\u00e9rdida de potencia.<\/p><p class=\"has-text-align-justify\" style=\"text-align: justify;\">No dude en contactarnos para obtener una explicaci\u00f3n m\u00e1s detallada de cada m\u00e9todo mencionado en IEC 60099-5.\u00a0IEC 60099-5 cl\u00e1usula 6.5 destaca una comparaci\u00f3n detallada de los diversos m\u00e9todos de medici\u00f3n de corriente de fuga.<\/p><p><img class=\"wp-image-260 size-full aligncenter\" src=\"https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/TABLA-3-ARMONICO.png\" alt=\"\" width=\"549\" height=\"299\" \/><\/p><p style=\"text-align: justify;\">De la tabla anterior se desprende que los m\u00e9todos B1 y B2 ofrecen los mejores resultados en comparaci\u00f3n con otros m\u00e9todos.<\/p><p class=\"has-text-align-justify\" style=\"text-align: justify;\">Sin embargo, el m\u00e9todo B2 proporciona un an\u00e1lisis de salud m\u00e1s preciso del pararrayos en comparaci\u00f3n con el m\u00e9todo B1, ya que el efecto \/ error de los arm\u00f3nicos presentes en el voltaje del sistema se compensa solo en el m\u00e9todo B2.<\/p><p class=\"has-text-align-justify\" style=\"text-align: justify;\">Por lo tanto, podemos concluir que el m\u00e9todo B2 es el mejor m\u00e9todo a seguir al evaluar la salud de los pararrayos.<\/p><p style=\"text-align: left;\"><strong><span class=\"has-inline-color has-luminous-vivid-orange-color\">ALCANCE SA 30i+<\/span><\/strong><\/p><p><img class=\"size-full wp-image-263 aligncenter\" src=\"https:\/\/equitest.co\/testing\/wp-content\/uploads\/2020\/09\/sa-30i-300x300-1.jpg\" alt=\"\" width=\"300\" height=\"300\" \/><\/p><p class=\"has-text-align-justify\" style=\"text-align: justify;\">SCOPE SA 30i+ es un analizador de corriente de fuga inal\u00e1mbrico de \u00faltima generaci\u00f3n dise\u00f1ado para evaluar la vida residual de los pararrayos de \u00f3xido de metal.<\/p><p class=\"has-text-align-justify\" style=\"text-align: justify;\">SA 30i+ mide con precisi\u00f3n y muestra directamente los valores de la corriente de fuga total y la corriente de fuga resistiva del tercer arm\u00f3nico junto con la compensaci\u00f3n arm\u00f3nica seg\u00fan IEC 60099-5-B2.<\/p><p class=\"has-text-align-justify\" style=\"text-align: justify;\">Dise\u00f1ado para trabajar bajo el ruido electrost\u00e1tico hostil que se encuentra en los patios de distribuci\u00f3n de EHV de hasta 765 kV, el SA 30i+ de SCOPE proporciona sin problemas Corriente de fuga resistiva corregida despu\u00e9s de aplicar los factores de correcci\u00f3n necesarios para los cambios en el voltaje y la temperatura del sistema. Para obtener m\u00e1s informaci\u00f3n, visite <a href=\"https:\/\/www.scopetnm.com\/test-and-measurements\/item\/75-sa-30i\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"has-inline-color has-vivid-cyan-blue-color\">https:\/\/www.scopetnm.com\/test-and-measurements\/item\/75-sa-30i<\/span><\/a> o escr\u00edbanos a equitest@equitest.co, Representante de SCOPE en Colombia.<\/p><\/div><\/div><\/div><\/div><\/div><\/div>","_et_gb_content_width":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-249","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-noticias"],"_links":{"self":[{"href":"https:\/\/equitest.co\/testing\/wp-json\/wp\/v2\/posts\/249","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/equitest.co\/testing\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/equitest.co\/testing\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/equitest.co\/testing\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/equitest.co\/testing\/wp-json\/wp\/v2\/comments?post=249"}],"version-history":[{"count":45,"href":"https:\/\/equitest.co\/testing\/wp-json\/wp\/v2\/posts\/249\/revisions"}],"predecessor-version":[{"id":5809,"href":"https:\/\/equitest.co\/testing\/wp-json\/wp\/v2\/posts\/249\/revisions\/5809"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/equitest.co\/testing\/wp-json\/wp\/v2\/media\/278"}],"wp:attachment":[{"href":"https:\/\/equitest.co\/testing\/wp-json\/wp\/v2\/media?parent=249"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/equitest.co\/testing\/wp-json\/wp\/v2\/categories?post=249"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/equitest.co\/testing\/wp-json\/wp\/v2\/tags?post=249"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}